Lipocontrol®

Lipocontrol® - FDA cleared, is the advanced device that allows optimization of lipolysis laser treatment. Thanks to its revolutionary and patented technology of control and regulation, the laser system shows an accurate and controlled on-screen amount of energy delivery for maximized results.  

Technology

Video on The Doctors:

Video on The Doctors:

Intended use and recommandation of Use

CE marking: The LIPOCONTROL laser is intended to be used for lipomes and gynecomastia treatment. 

FDA:  The intented use of Lipocontrol is laser assisted lipolysis. This laser assisted lipolysis device is only intended to be used on a small treatment area.  A  small  treatment  area  is  a  small  anatomical  site  such  as  the  chin  or  upper arms (triceps) that is treated to remove a total of about 120cc of fat per anatomic site.
 
The safety and effectiveness of laser assisted lipolysis on larger areas and laser assisted lipolysis procedures with liquefied fat remaining in the body or as an adjunct or  pre-treatment  for  standard  liposuction  procedures  have  not  been  evaluated  or cleared by the FDA.
The FDA has not evaluated clinical data demonstrating the safety and effectiveness of this device for larger volumes or areas of fat treatment such as thighs, buttocks, or abdomen.
 

Before and After Pictures

 

Advantages

Lipocontrol® offers :

  • Real-time visualization of the area to be treated on the screen, thanks to its tracking system, by magnetic field
  • Automatic adjustment of laser power to compensate the movement of cannula

- Laser power increased as speed of cannula increases, decreases as cannula slows down
- Laser power shuts off whenever the cannula stops moving over treated area

  • On-screen energy mapping which shows distribution energy in real-time for optimization of results. The visualization allows an homogenous distribution and avoid over treated areas..

Lipocontrol® offers the possibility to work in superficial plans and stimulate the collagen production with total safety and control. 

Technical Specifications

Laser:
Wavelenght:
Power:
Cooling system:
Emission mode:
Laser Class:

Safety class:
Aiming beam:
Wavelenght:
Aiming beam Laser class:
Power supply:
Weight:
Dimensions:
Certifications:

Diode Laser
980 nm nm +/-10
25 Watts
Peltier and Air
Continuous
4

IIb ( Directive 93/42/CE)
Diode Laser
635 nm +/- 20
3R
110-240 VAC ; 50 à 60 Hz
133 lbs
25 × 28 × 71 inches
FDA  - CE 0120